CBSJT - KODAK GBX FIXER AND REPLENISHER, CONCENTRATE
- MSDS: CBSJT
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: KODAK GBX FIXER AND REPLENISHER, CONCENTRATE
- National Stock Number: 6525-01-228-9865
Product Identification
Product ID:KODAK GBX FIXER AND REPLENISHER, CONCENTRATE
MSDS Date:11/15/1995
FSC:6525
NIIN:01-228-9865
MSDS Number: CBSJT
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 800- 242-2424
Cage: 19139
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 50-55%
AMMONIUM THIOSULFATE
CAS: 7783-18-8
RTECS: XN6465000
Fraction By Weight: 30-35%
SODIUM ACETATE
CAS: 127-09-3
RTECS: AJ4300010
Fraction By Weight: 1-5%
SODIUM BISULFITE
CAS: 7631-90-5
RTECS: VZ2000000
Fraction By Weight: 1-5%
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
AMMONIUM SULFITE
CAS: 10196-04-0
RTECS: WT3505000
Fraction By Weight: 1-5%
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE LOW HAZARD
FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN. MAY CAUSE
TRANSIENT IRRITATION. SKIN: LOW HAZARD FOR RECOMMENDED HANDLING.
INGESTION: EXPECTED TO BE A L OW INGESTION HAZARD.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION-IF SYMPTOMATIC, REMOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYES-ANY MATERIAL THAT CONTACTS THE
EYE SHOULD BE WASHED OUT IMMEDIATELY WITH WATER. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. SKIN-WASH WITH SOAP & WATER. GET
MEDCIAL ATTENTION IF SYMPTOMS OCCUR. INGESTED-DRINK 1-2 GLASSES OF
WATER. SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE. ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
INCOMPATIBLES SUBSTANCES.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELD.
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
Work Hygienic Practices:GOOD INDUSTRIAL HYGIENE PRACTICES TO MINIMIZE
SKIN CONTACT.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.28
pH:4.9
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, AMMONIA ODOR.
Percent Volatiles by Volume:50-55
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, BASES, SODIUM HYPOCHLORITE, STRONG OXIDIZING AGENTS.
CONTACT WITH BASE LIBERATES FLAMMABLE MATERIALS.
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:AMMONIA, NITROGEN OXIDES, SULFUR
DIOXIDE, CHLORAMINE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.